- 翻译公司资讯
-
世联翻译公司完成医疗“止血器”操作说明英文翻译
发布时间:2019-05-31 13:14 点击:
世联翻译公司完成医疗“止血器”操作说明英文翻译
Optical Coherence Tomography (OCT)System信息翻译Optical coherence tomography (OCT) system is the latest generation of intravascular imaging equipment which is designed based on advanced photonics and optical fiber technology. It uses near infrared ray to detect intravascular micron-level structures. The resolution is as high as 10-20um, much higher than any existing imaging technique, which is sufficient to meet clinical requirements. It can be used for early diagnosis of coronary heart disease, introducing implementation of interventional therapy and assessing therapeutic efficacy. OCT is manufactured by American Lightlab Imaging Corporation, and exclusively sold by Lepu (Beijing) Medical Devices Co., Ltd in China. 信息翻译Mobile M2CV OCT system cart includes a light source and a computer. On the top of cart there are two monitors, a storage drawer, a keyboard, a mouse and probe incorporation unit (PIU).Operation principle of OCTThe light source of OCT is near infrared light. It uses optical interference between reference light pulse and signal light pulse of detection object to measure structures of samples with different depths. Through longitudinal and axial scanning of probe or sample table, the obtained signal is processed by computer and three-dimensional CT images of the sample are generated.Accessories of OCT system:1. Imaging guide wireThe effect of imaging guide wire is to generate OCT image. Its outer layer is a plastic sheath, containing an optical fiber with a microprism at the front end. On the top of the guide wire there is a 15mm radiopaque spring tip. The maximum outer diameter of the insertable part of the guide wire is 0.019” (0.48mm) and the diameter at transparent sheath imaging window is 0.014” (0.36mm). The working length of imaging guide wire is 190 cm and the total length is 202 cm.2. Occlusion balloon catheter (OBC)Red blood cells in blood absorb infrared light, influencing vascular wall imaging. The effect of occlusion balloon catheter is to eliminate blood from imaging area. The blood expanded at low pressure can block proximal blood vessels in target lesions. Continuous transluminal low-volume washing can clear up blood in target lesions.3. LID-1 balloon pressure meterThe pressure gauge range of low-pressure expansion device for occlusion balloon expansion is 0-1.0 atm, and precision 0.05 atm.The pressure for occlusion balloon expansion during imaging and scanning should be lower than 0.5 atm.Clinical application of OCT1. To reveal morphology and nature of plaquesImage of fibrous plaque discovered in OCT imaging is an abundant homogeneous high-intensity zone; image of fibrous calcified plaque is a low-intensity zone with clear boundary; image of lipid plaque is a low-intensity zone with unclear boundary.2. To identify vulnerable plaquesPathological features of vulnerable plaques causing clinical emergencies mainly include: an atherosclerotic core composed of abundant extracellular lipid and cell debris (larger than 40% of total plaque volume), a thin fibrous cap (usually less than 65um) and massive infiltration of macrophages and T cells. OCT can well identify fibrous cap and lipid core (sensitivity above 90%) and discover plaque rupture.3. Application value of OCT in PCI treatmentOCT can observe poor stent adherence, intimal tear and tissue prolapse. It can assess stent adherence status by measuring the distance between stent beam and vascular wall.4. Application of OCT in PCI follow upReports of late-stage thrombosis caused by incomplete intimal coating on the surface of stent after implantation of drug-elute stent gradually increase. How to detect intimal coating status after drug-elute stent implantation is now the focus of attentions. OCT can observe the status of intimal restoration, providing powerful support in deciding withdrawal time of anti-platelet drugs.Now, the resolution of M2 OCT system is much higher than any existing cardiovascular imaging method. It can provide in vivo real-time micro images, realize more accurate assessment of plaque nature and vulnerable plaques and provide many images that are previously unavailable.Unitrans世联翻译公司在您身边,离您近的翻译公司,心贴心的专业服务,专业的全球语言翻译与信息解决方案供应商,专业翻译机构品牌。无论在本地,国内还是海外,我们的专业、星级体贴服务,为您的事业加速!世联翻译公司在北京、上海、深圳等国际交往城市设有翻译基地,业务覆盖全国城市。每天有近百万字节的信息和贸易通过世联走向全球!积累了大量政商用户数据,翻译人才库数据,多语种语料库大数据。世联品牌和服务品质已得到政务防务和国际组织、跨国公司和大中型企业等近万用户的认可。 专业翻译公司,北京翻译公司,上海翻译公司,英文翻译,日文翻译,韩语翻译,翻译公司排行榜,翻译公司收费价格表,翻译公司收费标准,翻译公司北京,翻译公司上海。